Serial Port Profiles
138 IOLAN SDS/SCS/STS User’s Guide, Version 3.6
Idle Timeout Use this timer to close a connection because of inactivity. When the Idle
Timeout
expires, the IOLAN will end the connection.
Range: 0-4294967 seconds (about 49 days)
Default:
0 seconds so the port will never timeout
Session Timeout Use this timer to forcibly close the session/connection when the Session
Timeout
expires.
Default:
0 seconds so the port will never timeout
Range: 0-4294967 seconds (about 49 days)
Dial Timeout The number of seconds the IOLAN will wait to establish a connection to a
remote modem.
Range: 1-99
Default: 45 seconds
Dial Retry The number of times the IOLAN will attempt to re-establish a connection with
a remote modem.
Range: 0-99
Default: 2
Dial In If the device is remote and will be dialing in via modem or ISDN TA, enable
this parameter.
Default: Disabled
Dial Out If you want the modem to dial a number when the serial port is started, enable
this parameter.
Default: Disabled